Project illustration
Industrial · Roof retention
Retention and stormwater for a paper mill
Montreal — Lachine
Roof retention and flow regulation, in line with City of Montreal requirements.
A permit application for a real estate project often requires civil plans: grading, drainage, service connections and stormwater management. We prepare the civil scope you need, coordinate it with the architecture and answer the municipality’s technical questions.
An engineer who is a member of the Ordre des ingénieurs du Québec · More than 10 years of experience · First reply within 48 hours
Around every building, you need to settle how the lot ties into the street, how water drains away and how the building connects to the networks. Civil plans for a building bring these elements together on signed and sealed plans, ready to be attached to the permit application.
Typical content of a civil plan
The grading plan sets the elevations of the lot, access and parking relative to the building and the street. It aims to move water away from the building and toward the planned collection points. See our page on site grading plans and layout.
Catch basins, pipes, roof water collection and discharge points: the site drainage network is designed together with the grading, so that both work as one. See drainage and stormwater management.
Sanitary, storm and water service connections have to account for the position, depth and capacity of the existing municipal networks. When grades do not allow gravity flow, pumping may be needed: we assess that need and coordinate it with the mechanical engineer. See site servicing: sewer, water and municipal connections.
Many municipalities limit the stormwater flow a project may discharge into their network. The permit file must then show how the project meets that limit: retained volume, retention structures and flow regulators, including roof target flows and discharge control.
See also our hydrologic calculations and stormwater retention.
In Montreal, By-law 20-030 governs, among other things, connections to municipal networks and stormwater management for projects. Elsewhere, each municipality applies its own requirements. We check which ones apply to your project and build them in from the design stage, rather than in response to a refusal.
When the project is subject to a PIIA (site planning and architectural integration program), the exterior work (grading, parking, retention structures) must also be consistent with the integration objectives.
A permit application often generates technical comments. We answer them directly, revise the plans as needed and keep the architect and the developer informed, so that the civil scope does not hold up the project.
Municipal support
When a site is developed in several buildings or several phases, the master plan sets the civil framework before the detailed plans: route of the networks, connection points, reference grades, location and volume of the retention structures. Each phase then ties into it without calling the earlier ones into question.
Master plan deliverables
The connection study compares the possible connection points, their elevations and their constraints. The phasing sets out what has to be built in the first phase, for example a retention structure or a main pipe, for the following phases to work.
Still assessing a lot, before starting design? See preconstruction and civil feasibility studies. This page deals with the plans required for a permit.
Your request is picked up within 48 hours: an engineer replies and agrees on the next step with you. This is the time to a first reply, not the time to a site visit or to delivery of the documents.
Once we have reviewed your request, the service proposal sets out the scope of the mandate, its steps and its schedule. We do not quote a standard turnaround before seeing the file.
An engineer who is a member of the Ordre des ingénieurs du Québec takes charge of your file and remains your contact throughout the mandate.
We compare the options, the quantities and their effect on construction costs, to settle on a solution that is compliant, durable and reasonable to build.
Project illustration
Industrial · Roof retention
Montreal — Lachine
Roof retention and flow regulation, in line with City of Montreal requirements.
When an authorization is needed, who reviews it and what documents to provide: what Montreal By-law 20-030 changes for stormwater management in projects.
Sewer depth, capacity, water main, storm discharge point: why check the municipal services before buying a lot or starting design.
Send us the architectural plans and the requirements you received from the municipality: we will tell you what the civil scope needs to include.